Redwall SIP-3020 - configure sensitivity

Print

Redwall SIP-3020 - configure sensitivity

This guide provides an overview of how the sensitivity settings can be adjusted on the Redwall SIP-3020 for optimal performance.

Overview of motion sensor features

Step 1. Remove the front cover

  1. Loosen the two screws for the front
  2. Grab the screw caps to loosen the front. The front is attached to the main unit with a nylon cord to prevent it from being dropped, so be careful when detaching.

Step 2. Set short and long distance sensitivity

The sensitivity can be set in four different modes for each distance (short or long)

  • SH - Extremely high sensitivity
  • H - High sensitivity
  • M - Normal sensitivity (default)
  • L - Low sensitivity

Choose the sensitivity that suits your conditions

Step 3. Set up detection logic

The sensor detects in two different planes in height to be able to create a correct detection depending on the situation and needs. To control this, there are two different logic modes that affect the detection

  • OR – The sensor triggers an alarm if anything moves in either of the two detection planes
    • Use this mode when setting up the detector (this is the default setting)
  • AND – The sensor triggers an alarm if movement is detected in both detection planes
    • Use this mode to avoid unnecessary false alarms