Optex LX-402/802N to IP camera

Print

Optex LX-402/802N to IP camera

This is a guide on how to physically install the LX-402/802N IR detector and connect it to your IP camera.

What you need:

  • IR detector
  • Cable for signal and power (included in the delivery)
  • Sugar Bite
  • Power adapter (12 V DC)

Step 1. Attach the IR detector and connect cables

  • Unscrew the screw at the bottom and carefully open the casing.

  • Attach the IR detector to the wall with the included screws or via a wall/ceiling mount. We recommend a height of 2 - 2.5 metres above the ground for best results.
  • Turn "Photocell" to "DAY" to enable round-the-clock detection

  • Thread the included 4-wire cord through the hole on the back
  • Connect green wire to "COM" and yellow wire to "N.C"
  • Connect red wire to + and black wire to -

  • Press the black sponge into the cable gland to seal against moisture
  • Close the lid and then screw in the screw again

Step 2. Connect power and IP camera

  • Connect the signal wires from the IR detector to the camera's "ALARM IN" and "GND" using a sugar cube.
  • Connect power (12 V DC) from the supplied power adapter to the detector using a sugar cube. Connect red to red and black to black.

  • Weatherproof the connections in a suitable junction box.

Step 3. Test the detector

  • Check that the detector is connected to power
  • Walk in front of the detector, if everything works properly, a red LED will flash
Table of Contents